CVE-2026-80754

CVE Details

Release Date:2026-09-03
Impact:Low What is this?

Description


In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts.

See more information about CVE-2026-80754 from MITRE CVE dictionary and NIST NVD


NOTE: The following CVSS metrics and score provided are preliminary and subject to review.


CVSS v3 metrics

Base Score: 7.1
Vector String: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Version: 3.1
Attack Vector: Local
Attack Complexity: Low
Privileges Required: Low
User Interaction: None
Scope: Unchanged
Confidentiality Impact: None
Integrity Impact: High
Availability Impact: High

Errata information


PlatformErrataRelease Date
Oracle Linux version 8 (kernel-uek) ELSA-2026-5002492026-09-04
Oracle Linux version 9 (kernel-uek) ELSA-2026-5002492026-09-04


This page is generated automatically and has not been checked for errors or omissions. For clarification or corrections:

software.hardware.complete